Hydraulic Service & Repair

On-Site Fault Finding and Commissioning

An engineer with gauges, a flow meter and a thermal camera on the machine, to find why a circuit is slow, hot or drifting, and to set a new circuit up properly.

Features

  • Measurement first: pressure at test points, flow where it can be taken, and case drain flow, which usually identifies the worn component within an hour.
  • Thermal readings across a valve bank show where power is being lost as heat, which is often a partly open relief rather than a failed pump.
  • Relief, compensator and port relief settings are recorded before anything is adjusted, so the machine can be put back if the fault lies elsewhere.
  • Commissioning of a new circuit covers filling through filtration, bleeding, setting pressures, and stroking every actuator under observed conditions.
  • The visit ends with a written record of settings and readings, which becomes the baseline for the next comparison.

Specifications

Figure Typical range Unit Why it matters
Symptom reported slow boom, oil at 85 degrees C directs which measurements are taken first
Measured pressures pump 210, relief cracking 195 bar separates a pump fault from a relief fault
Measured flow 62 against 80 rated l/min quantifies the loss instead of describing it
Case drain flow 6 against 2 expected l/min the quickest indicator of internal wear
Settings recorded before and after, per valve lets the machine be returned to its original state