Diaphragm Pumps

Electric mechanical diaphragm pump

The same mechanical diaphragm pump end driven by an electric motor, for sites with a supply. Quieter, with no exhaust, and suited to enclosed or occupied locations.

Features

  • No exhaust makes it usable in basements, shafts and enclosed structures where an engine cannot run at all.
  • Dry running remains harmless, so a float switch is a convenience rather than a protection requirement.
  • A 230 V single-phase motor at this size plugs into an ordinary site board without a starter.
  • Motor protection rating needs to suit a wet, splashed location even though the motor itself is not submerged.
  • Trailing cable is the practical limit on how far along a works it can be moved.

Specifications

Figure Typical range Unit Why it matters
Maximum flow 3 - 15 m³/h Matched to seepage rather than bulk water.
Motor rating 0.37 - 2.2 kW Small enough for a single-phase site board.
Supply voltage 230 / 1~ V Must match the site standard.
Motor protection rating IP 55 The location is wet even if the pump is not submerged.
Maximum solids size 6 - 15 mm Determined by the discharge bore.