Diesel Light Towers

Metal-halide diesel light tower

The older lamp technology, still specified where a very high point output is wanted from few fittings, or where an existing fleet is being matched. Cheaper per unit to buy and dearer to run.

Features

  • Typical fittings are 1 000 W or 1 500 W each, so a four-head tower draws 4 to 6 kW against roughly 1.2 kW for an LED tower that puts the same illuminance on the ground.
  • The engine and alternator are therefore much larger, and fuel use per hour is several times that of an LED tower.
  • Hot restrike takes several minutes, so any supply interruption puts the area in darkness for that time.
  • Lamp life is counted in thousands of hours and output falls measurably across it, so lamps are a scheduled consumable.
  • Lamps contain mercury and are a controlled waste stream, which adds a disposal obligation.
  • Where an existing fleet is halide, matching it keeps lamp stock and spares simple — that is usually the only reason to buy one now.

Specifications

Figure Typical range Unit Why it matters
Heads: number × rating 4 × 1 000 / 4 × 1 500 W Sets total electrical load and therefore engine size.
Total electrical load 4.0 - 6.0 kW Several times an equivalent LED tower.
Fuel consumption 1.4 - 2.6 l/h The main running-cost difference against LED.
Hot restrike delay 4 - 10 min Length of the blackout after any interruption.