Filtration & Accessories

Accumulators and Safety Blocks

Bladder, diaphragm and piston accumulators with mounting clamps, charging kits and safety blocks, for energy storage, pulsation damping and emergency lowering.

Features

  • Bladder types respond quickly and suit pulsation damping; piston types handle larger volumes and higher compression ratios.
  • Pre-charge is nitrogen only, and it is set against the minimum working pressure of the circuit, not against the maximum.
  • A charging and gauging kit is needed to check pre-charge, and pre-charge should be checked at a stated interval because it drops slowly.
  • A safety block with isolation and manual dump allows the stored energy to be released before anyone works on the circuit.
  • Emergency lowering circuits rely on accumulator capacity, so the volume is calculated from the cylinder's swept volume and the pressure available.

Specifications

Figure Typical range Unit Why it matters
Type bladder / piston decides response speed and usable volume
Nominal volume 1 - 50 l sets the stored energy available
Maximum working pressure 250 - 350 bar has to exceed the circuit relief setting
Pre-charge pressure 90 bar wrong pre-charge wastes capacity or destroys the bladder
Fluid port G 1 female fixes the mounting and pipework
Safety block fitted yes, with manual dump required before anyone can safely open the circuit