Filtration & Accessories

Offline Filtration Units

Trolley and fixed kidney-loop units that circulate reservoir oil through fine filtration or water removal while the machine keeps working. Used to recover oil rather than replace it.

Features

  • Circulating a reservoir several times through fine filtration removes particles that in-line filters recirculate.
  • Water-removing units separate free and dissolved water, which no particle filter will do.
  • A trolley unit can also be used to filter new oil into a machine, since new oil from a drum is often dirtier than the target cleanliness.
  • Flow rate and element size are matched to reservoir volume so a pass takes a sensible number of hours.
  • Sampling before and after gives a defensible before-and-after cleanliness figure rather than an impression of improvement.

Specifications

Figure Typical range Unit Why it matters
Flow rate 10 - 60 l/min with reservoir volume it sets the time for one pass
Filtration rating 3 micrometre finer than in-line filtration, because there is no pressure penalty
Water removal coalescing / vacuum only some units remove dissolved water
Reservoir volume served 200 - 4 000 l decides unit size and how long the job takes