Power Packs

Electric Power Packs

Three-phase and single-phase packs for workshops, test rigs, presses and fixed machinery, with the pump on a tank-top or immersed mounting and valving on the manifold.

Features

  • Tank-top mounting keeps the footprint small; immersed pumps run quieter and start more easily on cold oil.
  • Manifold-mounted valving reduces the number of joints, which is the main source of leaks on a pack that lives in a clean area.
  • Star-delta or soft starting is specified where the supply or the installation limits inrush current.
  • Thermostatic control of a heat exchanger is worth fitting on anything running more than a short cycle, because oil above about 60 degrees C ages quickly.
  • A drip tray and bunded base are often a site requirement rather than an option, and they change the frame dimensions.

Specifications

Figure Typical range Unit Why it matters
Motor power 4 kW checked against flow at working pressure
Supply 400 V 3 ph 50 Hz must match the site, including frequency
Flow at pressure 12 at 200 bar l/min flow alone is meaningless without the pressure it is delivered at
Reservoir volume 60 l sized on heat, not on pump flow alone
Cooling air blast, thermostat controlled keeps oil temperature inside the fluid's useful range