Filtration

Hydraulic and Transmission Filters

Pressure line, return line, suction and case drain elements plus transmission and final drive filters, with tank breathers and filler strainers.

Features

  • Element position decides construction: pressure elements are built for high differential, return elements are not, and swapping them collapses media.
  • The cleanliness target for a circuit is set by its most sensitive component, usually a servo valve or a piston pump.
  • Clogging indicators and differential pressure switches allow condition-based changes, which matters because hydraulic elements are expensive to change on schedule alone.
  • Tank breathers are part of the filtration system: unfiltered air drawn in overnight puts dust and moisture straight into the oil.
  • After a pump failure the circuit is flushed and elements are changed twice, because debris keeps circulating past the first change.

Specifications

Figure Typical range Unit Why it matters
Circuit position pressure / return / suction / case drain Sets pressure rating and construction.
Filtration rating 5 / 10 / 20 µm Cleanliness target for the circuit.
Collapse pressure 10 / 21 / 210 bar Element must survive the differential at that position.
Flow rate 40 - 400 l/min Restriction at working flow.
Bypass setting 1.7 / 3.5 bar Protects the element during cold start.