Irrigation & Transfer Pumps

High-pressure dust suppression pump

A pump producing the pressure a misting or spray-bar system needs to break water into droplets fine enough to bind dust. Specified in bar at the nozzle, not in flow.

Features

  • Droplet size, not water volume, is what captures dust, and droplet size comes from nozzle pressure — so pressure is the specification.
  • Misting systems commonly need 40 to 70 bar, which puts this in positive-displacement plunger pump territory rather than centrifugal.
  • Water quality decides nozzle life: fines and scale block fine nozzles quickly, so filtration ahead of the pump is mandatory.
  • Flow is low, and total water use is usually far below a conventional spray bar for the same dust reduction.
  • Freezing is the winter failure mode, so drain-down or trace heating is part of the installation.
  • Running against blocked nozzles raises pressure fast, so a relief valve set correctly is not optional.

Specifications

Figure Typical range Unit Why it matters
Operating pressure 40 - 70 bar Sets droplet size and therefore dust capture.
Flow 5 - 60 l/min Low by design; volume is not what captures dust.
Required inlet filtration 50 - 100 µm Fine nozzles block without it.
Relief valve setting set above operating pressure bar Protects the pump against blocked nozzles.
Drive power 1.5 - 15 kW Sizes the supply or engine.