Propulsion Engines

Keel-Cooled Engines for Workboats

Engines arranged for closed-circuit keel cooling and dry or partly dry exhaust, for tugs, dredgers and craft working in silty, weedy or debris-laden water.

Features

  • No raw water passes through the engine, so blocked strainers and impeller failures stop being a daily risk.
  • Cooler capacity is calculated from the heat to be rejected and the water temperature, and an undersized keel cooler cannot be corrected by anything on the engine.
  • Marine growth on the cooler surfaces reduces capacity over a season, so cleaning appears on the docking list rather than the service schedule.
  • Well suited to vessels that sit in shallow water or work close to a bank, where a raw-water intake picks up sand.
  • Dry exhaust with insulated lagging is common, which changes the engine room heat load and the ventilation requirement.

Specifications

Figure Typical range Unit Why it matters
Heat to be rejected as stated for the rating kW the figure the keel cooler is sized from
Design seawater temperature 25 - 32 degrees C cooler sizing depends on the warmest expected water
Cooler surface area as designed m2 cannot be increased once the hull is closed up
Exhaust arrangement dry, lagged drives engine room ventilation and heat load
Engine room ventilation as calculated m3/h a hot engine room de-rates the engine inside it