Auxiliary Engines & Generator Sets

Marine Generator Sets

Engine and alternator on a common bedframe with control panel, cooling and mounting arranged for marine installation, for ships' service and harbour load.

Features

  • Supplied as a matched set so governing, excitation and protection work together rather than being assembled from separate parts on board.
  • Heat exchanger or keel-cooled versions to suit the vessel's cooling arrangement and the water it works in.
  • Control panels range from manual start to automatic start and load transfer; the choice depends on whether an engineer is always on watch.
  • Sound shields reduce radiated noise where the set sits near accommodation, and they change the cooling air path.
  • Mounting on resilient mounts requires flexible fuel, exhaust and electrical connections, which are part of the order rather than site-made.

Specifications

Figure Typical range Unit Why it matters
Output 100 kVA at 0.8 power factor the figure the load study is checked against
Voltage and frequency 400 V, 50 Hz must match the vessel's distribution
Cooling heat exchanger / keel cooled decided by the water the vessel works in
Control panel automatic start with load transfer depends on whether the space is manned