Marine Service & Overhaul

Condition Monitoring

Oil and coolant sampling, vibration and temperature readings and performance logging, reported against running hours so overhauls can be scheduled rather than forced.

Features

  • Oil analysis identifies wear by metal type, which points at the component rather than at the engine in general.
  • Coolant analysis shows inhibitor depletion, which is what protects wet liners from cavitation damage.
  • Vibration and temperature readings taken at consistent points and loads make a trend readable.
  • Performance logging of fuel, exhaust temperature and speed at a known load shows fouling and injection drift early.
  • Reports are written to say what to do and when, not only what was measured.

Specifications

Figure Typical range Unit Why it matters
Parameters monitored oil, coolant, vibration, temperatures defines what the programme can detect
Sampling interval 250 / 500 h consistency is what makes a trend usable
Reference load for readings 75 % readings at different loads are not comparable
Action threshold per parameter, agreed at set-up turns a report into a decision